Acetic acid;2-dodecylguanidine
C15H33N3O2
acetic acid;2-dodecylguanidine
Consulting for Acetic acid;2-dodecylguanidine
Our experts support you with application, dosage, and compliance.
Identification
- CAS Number
- 2439-10-3
- EC Number
- 219-459-5
- UN Number
- 3077
- Index Number
- 607-076-00-X
- PubChem CID
- 17110
Physical-chemical properties
- Molecular Formula
- C15H33N3O2
- Molar Mass
- 287.44 g/mol
- IUPAC Name
- acetic acid;2-dodecylguanidine
Chemical Identifiers
- InChI
- InChI=1S/C13H29N3.C2H4O2/c1-2-3-4-5-6-7-8-9-10-11-12-16-13(14)15;1-2(3)4/h2-12H2,1H3,(H4,14,15,16);1H3,(H,3,4)
- InChI Key
- YIKWKLYQRFRGPM-UHFFFAOYSA-N
Overview
Acetic acid;2-dodecylguanidine (CAS 2439-10-3) is a guanidine derivative compound with antimicrobial properties and moderate toxicity profile. This chemical compound represents a combination of acetic acid with 2-dodecylguanidine, forming a salt that exhibits distinctive biocidal characteristics. With the molecular formula C15H33N3O2 and a molecular weight of 287.44 g/mol, this substance belongs to the class of alkylguanidine compounds known for their antimicrobial efficacy. The dodecyl chain provides lipophilic properties that enhance membrane interaction, while the guanidine moiety contributes to the compound's biological activity. The safety profile of acetic acid;2-dodecylguanidine requires careful handling protocols due to its classification under several hazard categories. It presents acute toxicity concerns (Acute Tox. 4), causes skin and eye irritation (Skin Irrit. 2, Eye Irrit. 2), and poses significant environmental risks to aquatic organisms with both acute and chronic toxicity (Aquatic Acute 1, Aquatic Chronic 1). The compound carries a Warning signal word and is associated with GHS07 and GHS09 pictograms, indicating health hazards and environmental dangers respectively. Its ADR classification as Class 9 designates it as a miscellaneous dangerous substance for transportation purposes. Industrial applications primarily focus on antimicrobial formulations, including disinfectants and preservative systems where controlled biocidal activity is required. The compound also finds use in specialized cleaning formulations and as an active ingredient in certain industrial biocides. Unlike more aggressive biocides such as 2,4,5-trichlorophenol, this guanidine derivative offers a more controlled antimicrobial profile suitable for specific applications. OYSI provides reliable access to acetic acid;2-dodecylguanidine for European industrial customers requiring this specialized antimicrobial compound.
Safety & Classification
Acute Tox. 4 *; Skin Irrit. 2; Eye Irrit. 2; Aquatic Acute 1; Aquatic Chronic 1
GHS Pictograms
HHazard Statements (H-Statements)
Describe the nature and severity of the hazard
Classification according to CLP Regulation (EC) No 1272/2008. The complete list of hazard and precautionary statements can be found in the Safety Data Sheet (SDS).
First Aid Measures
Skin Contact
Measures if substance contacts the skin
First Aid Actions
- +P302IF ON SKIN:
- +P352Wash with plenty of water.
- +P361Take off immediately all contaminated clothing.
- +P313Get medical advice/attention.
Related hazard statements:
Eye Contact
Measures if substance gets into the eyes
First Aid Actions
- +P305IF IN EYES:
- +P351Rinse cautiously with water for several minutes.
- +P338Remove contact lenses, if present and easy to do. Continue rinsing.
- +P313Get medical advice/attention.
Related hazard statements:
Ingestion
Measures if substance is accidentally swallowed
First Aid Actions
- +P301IF SWALLOWED:
- +P330Rinse mouth.
- +P331Do NOT induce vomiting.
- +P310Immediately call a POISON CENTER/doctor.
Related hazard statements:
General Measures
Emergency 112 | Poison Control: +49 30 19240 (DE), +33 1 45 42 59 59 (FR), +31 30 274 88 88 (NL)
First aid measures are based on CLP classification and associated P-statements. They do not replace the Safety Data Sheet (SDS). In case of emergency, always consult the full SDS and a physician.
Transport (ADR)
| UN Number | 3077 |
| ADR Class | 9 |
| Packing Group | III |
| Tunnel Code | - |
| Proper Shipping Name | Dodin (ISO) |
| Marine Pollutant | No |
Frequently Asked Questions
What is acetic acid;2-dodecylguanidine?
Acetic acid;2-dodecylguanidine is an organic compound with CAS number 2439-10-3 and molecular formula C15H33N3O2. This chemical substance has a molecular weight of 287.44 g/mol and belongs to the guanidine derivative family. It is classified as a hazardous substance with moderate toxicity and irritant properties. The compound requires careful handling due to its potential health and environmental impacts, particularly its acute aquatic toxicity.
What are the physicochemical properties of acetic acid;2-dodecylguanidine?
Acetic acid;2-dodecylguanidine is a chemical compound with molecular formula C15H33N3O2 and molecular weight 287.44 g/mol. The substance contains both hydrophilic (guanidine and acetate groups) and hydrophobic (dodecyl chain) components, suggesting amphiphilic properties. Its long alkyl chain indicates potential surfactant-like behavior. Specific physical properties such as melting point, boiling point, and exact solubility data require consultation of detailed technical specifications.
What is acetic acid;2-dodecylguanidine used for?
Acetic acid;2-dodecylguanidine is primarily used as a surfactant and antimicrobial agent in various industrial applications. The compound's structure, featuring a long alkyl chain and guanidine group, makes it suitable for formulations requiring both surface-active and biocidal properties. It may be employed in cleaning products, disinfectants, and specialty chemical formulations. Its specific applications depend on the required antimicrobial efficacy and surface tension modification properties.
How to handle acetic acid;2-dodecylguanidine safely?
Acetic acid;2-dodecylguanidine requires standard chemical safety precautions due to its Acute Tox. 4, Skin Irrit. 2, and Eye Irrit. 2 classifications. Wear appropriate personal protective equipment including chemical-resistant gloves, safety goggles, and protective clothing. Ensure adequate ventilation in work areas and avoid direct contact with skin and eyes. Handle in well-ventilated areas and follow good industrial hygiene practices. Emergency washing facilities should be readily accessible.
How to store acetic acid;2-dodecylguanidine correctly?
Acetic acid;2-dodecylguanidine should be stored in original, tightly sealed containers in a cool, dry, well-ventilated area away from incompatible materials. Keep containers away from heat sources, direct sunlight, and ignition sources. Store separately from strong acids, bases, and oxidizing agents to prevent unwanted reactions. Ensure storage area is equipped with appropriate spill containment measures and restrict access to authorized personnel only.
What to do in case of contact with acetic acid;2-dodecylguanidine?
Acetic acid;2-dodecylguanidine contact requires immediate action due to its irritant properties. For skin contact, immediately remove contaminated clothing and rinse affected area with plenty of water for at least 15 minutes. In case of eye contact, flush immediately with clean water for at least 15 minutes while holding eyelids open. If inhaled, move to fresh air immediately. Seek medical attention if irritation persists or if large quantities were involved.
How to dispose of acetic acid;2-dodecylguanidine appropriately?
Acetic acid;2-dodecylguanidine disposal must comply with local, national, and international waste regulations due to its hazardous classification. The substance cannot be disposed of as regular waste and requires specialized hazardous waste treatment. Contact licensed waste disposal companies for proper handling and disposal. Empty containers may also require special disposal procedures. Never discharge into drains, waterways, or soil due to its aquatic toxicity classification.
How to transport acetic acid;2-dodecylguanidine?
Acetic acid;2-dodecylguanidine is classified as ADR Class 9 (Miscellaneous dangerous goods), Packing Group III for transportation purposes. This classification requires specific packaging, labeling, and documentation according to international dangerous goods regulations. Transport vehicles must display appropriate hazard placards and carry emergency response information. Only trained personnel should handle transportation, and shipments must comply with ADR/RID regulations for road and rail transport within Europe.
Is acetic acid;2-dodecylguanidine subject to specific regulations?
Acetic acid;2-dodecylguanidine is subject to European REACH and CLP regulations due to its hazardous properties. The substance is not currently listed as a Substance of Very High Concern (SVHC). Companies must comply with registration, evaluation, and authorization requirements under REACH. Classification and labeling must follow CLP regulation with Warning signal word and GHS07/GHS09 pictograms. Users must maintain safety data sheets and implement appropriate risk management measures.
Where to buy acetic acid;2-dodecylguanidine in Europe?
Acetic acid;2-dodecylguanidine is available through OYSI, a specialized European distributor of technical chemicals. OYSI provides this substance to industrial customers across Europe with full regulatory compliance and technical support. As a professional chemical distributor, OYSI ensures proper packaging, documentation, and handling of hazardous materials according to European regulations. Contact OYSI directly for availability, specifications, and ordering information for your specific application requirements.
Services for Acetic acid;2-dodecylguanidine
Order Acetic acid;2-dodecylguanidine
Fast delivery across Europe
SDS Service
Request Safety Data Sheet for Acetic acid;2-dodecylguanidine
Technical Consulting
Application advice for Acetic acid;2-dodecylguanidine
REACH Safety Data Sheet
REACH Compliance Service
Digital Product Passport
EU-compliant product documentation
ADR Consulting for Acetic acid;2-dodecylguanidine
Acetic acid;2-dodecylguanidine is a dangerous good. We support you with labeling, packaging, and transport documentation.
Data Sources
Classification per CLP Regulation (EC) No 1272/2008. Data from ECHA and PubChem.