2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate

C15H24O6

CAS42978-66-5
GHS07 Gefahrensymbol: Gesundheitsschädlich/Reizend – Ausrufezeichen
GHS09 Gefahrensymbol: Umweltgefährlich – Umwelt
Warning

Consulting for 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate

Our experts support you with application, dosage, and compliance.

Request Consultation

Identification

CAS Number
42978-66-5
EC Number
256-032-2
UN Number
3082
Index Number
607-249-00-X
PubChem CID
4128060

Physical-chemical properties

Molecular Formula
C15H24O6
Molar Mass
300.35 g/mol
IUPAC Name
2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate

Chemical Identifiers

InChI
InChI=1S/C15H24O6/c1-6-14(16)20-9-12(4)18-8-11(3)19-10-13(5)21-15(17)7-2/h6-7,11-13H,1-2,8-10H2,3-5H3
InChI Key
LJRSZGKUUZPHEB-UHFFFAOYSA-N

Overview

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate (CAS 42978-66-5) is a diacrylate ester compound with crosslinking properties and moderate toxicity classification. This specialized chemical compound belongs to the family of acrylate esters, characterized by its complex molecular structure containing two reactive acrylate functional groups connected through a propylene glycol chain. With a molecular formula of C15H24O6 and molecular weight of 300.35 g/mol, this diacrylate demonstrates versatile reactivity patterns that make it valuable in various industrial polymerization processes. The compound exhibits moderate hazard characteristics, classified under GHS pictograms GHS07 and GHS09 with a "Warning" signal word. Safety considerations include skin and eye irritation potential (Skin Irrit. 2, Eye Irrit. 2), skin sensitization properties (Skin Sens. 1), and specific target organ toxicity (STOT SE 3). Additionally, it presents chronic aquatic toxicity concerns (Aquatic Chronic 2), requiring appropriate handling protocols and environmental precautions during use and disposal. Industrial applications primarily focus on UV-curable coatings, adhesives, and polymer synthesis where crosslinking functionality is essential. The compound serves as an effective crosslinking agent in radiation-curing formulations, providing enhanced mechanical properties and chemical resistance to final products. Similar to other acrylate compounds like hexyl prop-2-enoate, it contributes to rapid polymerization processes under appropriate curing conditions. The dual acrylate functionality enables formation of three-dimensional polymer networks, making it particularly suitable for applications requiring durability and performance characteristics in protective coatings and specialty adhesive formulations. OYSI maintains reliable supply chains for this technical-grade chemical compound to support European industrial customers' specialized formulation requirements.

Safety & Classification

Warning
Classification:

STOT SE 3; Skin Irrit. 2; Eye Irrit. 2; Skin Sens. 1; Aquatic Chronic 2

HHazard Statements (H-Statements)

Describe the nature and severity of the hazard

H335

May cause respiratory irritation.

H315

Causes skin irritation.

H319

Causes serious eye irritation.

H317

May cause an allergic skin reaction.

H411

Toxic to aquatic life with long lasting effects.

Classification according to CLP Regulation (EC) No 1272/2008. The complete list of hazard and precautionary statements can be found in the Safety Data Sheet (SDS).

First Aid Measures

Inhalation

Irritant

Measures if vapours or dust are inhaled

First Aid Actions

  • +P304IF INHALED:
  • +P340Remove person to fresh air and keep comfortable for breathing.
  • +P311Call a POISON CENTER/doctor.

Related hazard statements:

Skin Contact

Irritant

Measures if substance contacts the skin

First Aid Actions

  • +P302IF ON SKIN:
  • +P352Wash with plenty of water.
  • +P361Take off immediately all contaminated clothing.
  • +P313Get medical advice/attention.

Related hazard statements:

Eye Contact

Irritant

Measures if substance gets into the eyes

First Aid Actions

  • +P305IF IN EYES:
  • +P351Rinse cautiously with water for several minutes.
  • +P338Remove contact lenses, if present and easy to do. Continue rinsing.
  • +P313Get medical advice/attention.

Related hazard statements:

General Measures

Emergency 112 | Poison Control: +49 30 19240 (DE), +33 1 45 42 59 59 (FR), +31 30 274 88 88 (NL)

First aid measures are based on CLP classification and associated P-statements. They do not replace the Safety Data Sheet (SDS). In case of emergency, always consult the full SDS and a physician.

Transport (ADR)

UN Number3082
ADR Class9
Packing GroupIII
Tunnel Code-
Proper Shipping Name(1-Methyl-1,2-ethandiyl)bis[oxy-(methyl-2,1-ethandiyl)]diacrylat
Marine PollutantNo

Frequently Asked Questions

What is 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is a complex organic compound with the molecular formula C15H24O6 and CAS number 42978-66-5. This chemical belongs to the family of acrylate esters, featuring multiple propoxy groups and acrylate functionalities. With a molecular weight of 300.35 g/mol, it presents moderate hazard properties including skin and eye irritation, skin sensitization, and specific target organ toxicity.

What are the physicochemical properties of 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is typically a liquid at room temperature due to its complex ester structure and molecular weight of 300.35 g/mol. As an acrylate compound, it likely exhibits limited water solubility but good solubility in organic solvents. The presence of multiple ether and ester linkages contributes to its flexibility and relatively low volatility compared to simpler acrylates.

What is 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate used for?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is primarily used as a reactive monomer in polymer synthesis and coating applications. Its multiple acrylate groups enable crosslinking reactions, making it valuable for UV-curable coatings, adhesives, and specialty polymers. The compound's flexible structure from propoxy linkages provides enhanced film properties and durability in industrial formulations requiring specific mechanical and chemical resistance characteristics.

How to handle 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate safely?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate requires careful handling due to its skin and eye irritation potential and sensitizing properties. Essential protective equipment includes chemical-resistant gloves, safety goggles, and protective clothing to prevent skin contact. Work in well-ventilated areas to minimize inhalation exposure. Avoid contact with skin and eyes, and wash hands thoroughly after handling. Use appropriate respiratory protection if ventilation is inadequate.

How to store 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate correctly?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate should be stored in a cool, dry, well-ventilated area away from heat sources and direct sunlight to prevent polymerization. Keep containers tightly closed and protect from temperature extremes. Store separately from strong oxidizers and incompatible materials. Use original containers or approved chemical-resistant containers. Implement proper inventory rotation and regularly inspect containers for integrity to prevent leaks or contamination.

What to do in case of contact with 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate?

Skin contact with 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate requires immediate removal of contaminated clothing and thorough washing with soap and water for at least 15 minutes. For eye contact, flush immediately with clean water for 15-20 minutes and remove contact lenses if present. If inhaled, move to fresh air immediately. Seek medical attention if irritation persists or if symptoms develop, especially considering the compound's sensitizing properties.

How to dispose of 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate properly?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate must be disposed of according to local and national hazardous waste regulations. Contact licensed waste disposal companies for proper treatment and disposal. Do not discharge to sewers, waterways, or soil due to its aquatic toxicity classification (Aquatic Chronic 2). Small quantities may be suitable for incineration at approved facilities. Always consult local environmental authorities for specific disposal requirements and maintain proper documentation.

How to transport 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is classified as ADR Class 9 (Miscellaneous Dangerous Goods), Packing Group III for transport purposes. This classification requires appropriate packaging, labeling, and documentation according to dangerous goods regulations. Use UN-approved packaging and ensure proper marking and placarding on transport vehicles. Transport documentation must include safety data sheets and emergency response information. Follow all applicable national and international transport regulations for hazardous materials.

Is 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate subject to special regulations?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is subject to standard REACH registration and CLP classification requirements in Europe but is not currently listed as a Substance of Very High Concern (SVHC). It must be classified and labeled according to its hazard properties (STOT SE 3, Skin Irrit. 2, Eye Irrit. 2, Skin Sens. 1, Aquatic Chronic 2). Users must comply with occupational exposure limits and workplace safety regulations applicable to sensitizing substances.

Where to buy 2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate in Europe?

2-[2-(2-prop-2-enoyloxypropoxy)propoxy]propyl prop-2-enoate is available through OYSI, a specialized European distributor of technical chemicals and intermediates. OYSI provides reliable supply chains across Europe with proper regulatory compliance and technical support. As a professional chemical distributor, OYSI ensures appropriate packaging, documentation, and handling procedures for this regulated substance. Contact OYSI directly for availability, technical specifications, and delivery options tailored to your specific requirements.

Data Sources

Classification per CLP Regulation (EC) No 1272/2008. Data from ECHA and PubChem.